Activity

  • Mead posted an update 9 months, 1 week ago

    The method for the determination of primaquine (PQ) and 5,6-orthoquinone primaquine (5,6-PQ), the representative marker for PQ active metabolites, via CYP2D6 in human plasma and urine has been validated. All samples were extracted using acetonitrile for protein precipitation and analyzed using the ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) system. Chromatography separation was carried out using a Hypersil GOLDTM aQ C18 column (100 × 2.1 mm, particle size 1.9 μm) with a C18 guard column (4 × 3 mm) flowed with an isocratic mode of methanol, water, and acetonitrile in an optimal ratio at 0.4 mL/min. The retention times of 5,6-PQ and PQ in plasma and urine were 0.8 and 1.6 min, respectively. The method was validated according to the guideline. The linearity of the analytes was in the range of 25-1500 ng/mL. The matrix effect of PQ and 5,6-PQ ranged from 100% to 116% and from 87% to 104% for plasma, and from 87% to 89% and from 86% to 87% for urine, respectively. The recovery of PQ and 5,6-PQ ranged from 78% to 95% and form 80% to 98% for plasma, and from 102% to from 112% to 97% to 109% for urine, respectively. The accuracy and precision of PQ and 5,6-PQ in plasma and urine were within the acceptance criteria. The samples should be kept in the freezer (-80 °C) and analyzed within 7 days due to the metabolite stability. GSK650394 This validated UHPLC-MS/MS method was beneficial for a pharmacokinetic study in subjects receiving PQ.Ten derivatives of p-aminocinnamic aldehydes were prepared from the reaction of either aromatic amines with dimethylaminoacrolein or benzaldehydes with acetaldehyde. Their chemical structure and purity were verified by 1H NMR, 13C NMR and IR spectroscopic methods. We found that the synthesis applying dimethylaminoacrolein as the reagent gets better yields than the one based on the reaction with acetaldehyde. The yields of the cinnamic aldehydes varied according to the type of the amino group and the number and position of the substituents. The basic spectroscopic properties of the p-aminocinnamic aldehydes are also described since the compounds may be a precursor for the synthesis of dyes for diverse applications, e.g., in medicine and optoelectronics.Monitoring and quantification of active pharmaceutical ingredients (APIs) in the environment constitute important and challenging tasks, as they are directly associated with human health. Three commonly used proton pump inhibitors (PPIs), namely, omeprazole sodium (OMP), pantoprazole sodium (PNT), and lansoprazole sodium (LNZ) are well separated and quantified using ultra-performance liquid chromatography (UPLC) in pharmaceutical industrial wastewater. The separation of the studied drugs was performed on a stationary phase with a WatersTM column (100 × 2.1 mm, 1.7 µm). The mobile phase was composed of methanol0.05 M potassium dihydrogen phosphate buffer (adjusted to pH 7.5 using NaOH) (5050, v/v). The elution process was done in gradient mode by changing the relative proportions of the mobile phase components with time to get an optimum separation pattern. The flow rate of the developing system was adjusted to 0.8 mL/minute. Detection of the separated drugs was performed at 230 nm. The studied drugs were quantified in the concentration range of 10-200 ng/mL for all drugs. The cited method was fully validated according to the international conference on harmonization (ICH-Q2B) guidelines, then it was applied successfully for quantification of the studied PPIs in real wastewater samples after their solid phase extraction (SPE).Efficient repetitive clinical use of morphine is limited by its numerous side effects, whereas analgesic tolerance necessitates subsequent increases in morphine dose to achieve adequate levels of analgesia. While many studies focused on analgesic tolerance, the effect of morphine dosing on non-analgesic effects has been overlooked. This study aimed to characterize morphine-induced behavior and the development and progression of morphine-induced behavioral tolerance. Adult male Sprague-Dawley rats were repetitively treated with subcutaneous morphine for 14 days in two dose groups (A 5 mg/kg/day (b.i.d.) → 10 mg/kg/day; B 10 mg/kg/day (b.i.d.) → 20 mg/kg/day). Motor behavior was assessed daily (distance traveled, speed, moving time, rearing, rotation) in an open-field arena, before and 30 min post-injections. Antinociception was measured using tail-flick and hot-plate assays. All measured parameters were highly suppressed in both dosing groups on the first treatment day, followed by a gradual manifestation of behavioral tolerance as the treatment progressed. Animals in the high-dose group showed increased locomotor activity after 10 days of morphine treatment. This excitatory phase converted to an inhibition of behavior when a higher morphine dose was introduced. We suggest that the excitatory locomotor effects of repetitive high-dose morphine exposure represent a signature of its behavioral and antinociceptive tolerance.The evaluation of groundwater quality in the Dammam formation, Faddak farm, Karbala Governorate, Iraq proved that the sulfate (SO42-) concentrations have high values; so, this water is not suitable for livestock, poultry and irrigation purposes. For reclamation of this water, manufacturing of new sorbent for permeable reactive barrier was required through precipitation of Mg and Fe hydroxides nanoparticles on the activated carbon (AC) surface with best Mg/Fe molar ratio of 7.5/2.5. Mixture of 50% coated AC and 50% scrap iron was applied to eliminate SO42- from contaminated water with efficiency of 59% and maximum capacity of adsorption equals to 9.5 mg/g for a time period of 1 h, sorbent dosage 40 g/L, and initial pH = 5 at 50 mg/L initial SO42- concentration and 200 rpm shaking speed. Characterization analyses certified that the plantation of Mg and Fe nanoparticles onto AC was achieved. Continuous tests showed that the longevity of composite sorbent is increased with thicker bed and lower influent concentration and flow rate. Computer solution (COMSOL) software was well simulated for continuous measurements. The reclamation of real contaminated groundwater was achieved in column set-up with efficiency of 70% when flow rate was 5 mL/min, bed depth was 50 cm and inlet SO42- concentration was 2301 mg/L.

Skip to toolbar