Davidson posted an update 7 months, 1 week ago
16,
= 0.02,
< 0.001, and probability of unemployment, β = 1.14,
= 0.001,
< 0.001.
This is the first study to introduce a cognitive staging and stratification system for MS. Findings underscore the importance of using the Symbol Digit Modalities Test in routine screening for cognitive impairment and memory testing to assess patients later in disease evolution.
This is the first study to introduce a cognitive staging and stratification system for MS. Findings underscore the importance of using the Symbol Digit Modalities Test in routine screening for cognitive impairment and memory testing to assess patients later in disease evolution.United States Pharmacopeia (USP) Chapter for hazardous drug (HD) handling in healthcare settings requires HD be primed intravenously with a non-HD solution prior to dispensing. This review details our clinic’s algorithm for determining tubing needs for medications used in an hematology oncology clinic. Factors to consider are volume, irritant and vesicant properties, and compatibility with hydration solution.
Contrast-induced acute kidney injury (CI-AKI) is a life-threatening complication that leads to comorbidities and prolonged hospital stay lengths in the setting of peripheral interventions. The presence of some CI-AKI risk factors has already been investigated. In this study, we evaluated the predictors of CI-AKI after carotid artery stenting.
A total of 389 patients with 50% to 99% carotid artery stenosis who underwent carotid artery stenting were included in this study. Patients were grouped according to CI-AKI status.
CI-AKI developed in 26 (6.6%) patients. Age, baseline creatinine level, neutrophil-to-lymphocyte ratio and platelet-to-lymphocyte ratio were higher and estimated glomerular filtration rate, haemoglobin and lymphocyte count were lower in CI-AKI patients. In the multivariate regression analysis, the neutrophil-to-lymphocyte ratio triggered a 1.39- to 2.63-fold increase in the risk of CI-AKI onset (
< 0.001).
The neutrophil-to-lymphocyte ratio may be a significant predictor of CI-AKI in patients with carotid artery stenting and higher neutrophil-to-lymphocyte ratio values may be independently associated with CI-AKI.
The neutrophil-to-lymphocyte ratio may be a significant predictor of CI-AKI in patients with carotid artery stenting and higher neutrophil-to-lymphocyte ratio values may be independently associated with CI-AKI.
Fragile soft clots and stiff clots remain challenging in the treatment of acute ischemic stroke. This study aims to investigate the impact of clot stiffness on the efficacy of thrombectomy devices and a new aspiration catheter with a hydro-separator.
The Neurostar aspiration catheter has a novel hydro-separator technology that macerates clots by a stream of saline inside the catheter. The Neurostar catheter and two commercially available devices, the SOFIA aspiration catheter and Solitaire stent retriever, were tested in this study. We evaluated the efficacy of each device on clots with various stiffness in a simple in vitro model. We also assessed single-pass recanalization performance in challenging situations with large erythrocyte-rich clots and fibrin-rich clots in a realistic vascular model.
We observed an inverse association between the clot stiffness and recanalization rates. The aspiration catheter, SOFIA ingested soft clots but not moderately stiff clots. When removing soft clots with the stent retriever, fragmentation was observed, although relatively stiff clots were well-integrated and removed. The Neurostar ingested soft clots similar to the aspiration catheter, and also aspirated stiff clots by continuous suction with hydro-separator. In the experiments with challenging clots, the Neurostar led to significantly higher recanalization rates than the stent retriever and aspiration catheter.
The stiffness of the clots affected the efficacy of endovascular thrombectomy based on the type of device. The Neurostar catheter with hydro-separator resulted in better success rates than a commercially available aspiration catheter and stent retriever in this experimental model.
The stiffness of the clots affected the efficacy of endovascular thrombectomy based on the type of device. The Neurostar catheter with hydro-separator resulted in better success rates than a commercially available aspiration catheter and stent retriever in this experimental model.
Flow diversion of aneurysms located in the M1 segment and middle cerebral artery bifurcation with Pipeline embolization device is sometimes performed, but further study is needed to support its regular use in aneurysm treatment. Here, we report measures of safety and efficacy for Pipeline embolization in the proximal middle cerebral artery in a multi-center cohort.
Clinical and angiographic data of eligible patients were retrospectively obtained from participating centers and assessed for key clinical and angiographic outcomes. Additional details were extracted for patients with complications.
In our multi-center cohort, complete aneurysm occlusion was achieved in 71% (17/24) of treated aneurysms. MK-0991 There were no deaths or disabling strokes, but non-disabling ischemic strokes occurred in 8% (2/24) of patients. For aneurysms in the M1 segment, complete aneurysm occlusion was observed in 75% (12/16) of aneurysms, aneurysm volume reduction was observed in 100% (16/16) of aneurysms, and non-disabling ischemic strokes occurred in 13% (2/16) of patients. For aneurysms at the middle cerebral artery bifurcation, complete aneurysm occlusion was observed in 63% (5/8) of aneurysms, aneurysm volume reduction occurred in 88% (7/8) of aneurysms, and ischemic or hemorrhagic complications occurred in 0% (0/8) of patients.
Pipeline embolization of cerebral aneurysms in the M1 segment and middle cerebral artery bifurcation demonstrated a 71% rate of complete aneurysm occlusion. There were no deaths or disabling strokes, but there was an 8% rate of non-disabling ischemic strokes.
Pipeline embolization of cerebral aneurysms in the M1 segment and middle cerebral artery bifurcation demonstrated a 71% rate of complete aneurysm occlusion. There were no deaths or disabling strokes, but there was an 8% rate of non-disabling ischemic strokes.