    To investigate the effects of a reduced field-of-view (rFOV) acquisition in diffusion-weighted magnetic resonance imaging of the pancreas.

    We enrolled 153 patients who underwent routine clinical MRI work-up including respiratory-triggered diffusion-weighted single-shot echo-planar imaging (DWI) with full field-of-view (fFOV, 3 × 3 × 4 mm

    voxel size) and reduced field-of-view (rFOV, 2.5 × 2.5 × 3 mm

    voxel size) for suspected pancreatic pathology. Two experienced radiologists were asked to subjectively rate (Likert Scale 1-4) image quality (overall image quality, lesion conspicuity, anatomical detail, artifacts). In addition, quantitative image parameters were assessed (apparent diffusion coefficient, apparent signal to noise ratio, apparent contrast to noise ratio [CNR]).

    All subjective metrics of image quality were rated in favor of rFOV DWI images compared to fFOV DWI images with substantial-to-high inter-rater reliability. Calculated ADC values of normal pancreas, pancreatic pathologies and reference tissues revealed no differences between both sequences. Whereas the apparent signal to noise ratio was higher in fFOV images, apparent CNR was higher in rFOV images.

    rFOV DWI provides higher image quality and apparent CNR values, favorable in the analysis of pancreatic pathologies.

    rFOV DWI provides higher image quality and apparent CNR values, favorable in the analysis of pancreatic pathologies.

    To evaluate whether pregestational obesity is associated with the risk of caesarean section in pregnant women living in a country in an advanced stage of the obstetric transition.

    Retrospective cohort study. Data were collected from prenatal and hospital records. Pregestational obesity was defined as body mass index, [weight(k)/height (m

    )] ≥30, and caesarean sections were categorized as elective, emergency, or non-emergency/medically necessary. Biodemographic and sociodemographic characteristics, obstetric and perinatal pathologies, and maternal anthropometric variables were assessed. Chi-square and t-tests were used to compare qualitative and quantitative variables, respectively. Simple and adjusted generalized linear models were used to evaluate the association between pregestational obesity and caesarean delivery. Finally, population attributable risk was calculated. Data analysis was performed using STATA.v.14.0.

    2309 pregnant women with a singleton pregnancy who gave birth at a public hospital inease obstetric intervention.Obesity has emerged as a significant risk factor for severe COVID-19 worldwide. Given both COVID-19 infection and obesity have been associated with increased systemic inflammation, we evaluated inflammatory markers in obese and non-obese individuals hospitalized for COVID-19 at Massachusetts General Hospital. We hypothesized that obese patients would have a more exuberant inflammatory response as evidenced by higher initial and peak inflammatory markers along with worse clinical outcomes. Of the 781 patients, 349 were obese (45%). Obese individuals had higher initial and peak levels of CRP and ESR as well as higher peak d-dimer (P less then 0.01 for all) in comparison to non-obese individuals, while. IL-6 and ferritin were similar. In addition, obese individuals had a higher odds of requiring vasopressor use (OR 1.54, 95% CI 1.00-2.38, P = 0.05), developing hypoxemic respiratory failure (OR 1.58, 95% CI 1.04-2.40, P = 0.03) and death (OR 2.20, 95% CI 1.31-3.70, P = 0.003) within 28 days of presentation to care. Finally, higher baseline levels of CRP and D-dimer were associated with worse clinical outcomes even after adjustment for BMI. Our findings suggest greater disease severity in obese individuals is characterized by more exuberant inflammation.Image-guided radiotherapy (IGRT) has become a standard irradiation technique to improve the clinical outcome of patients in terms of toxicity and local control due to better targeting of radiation during the irradiation fraction. Positioning imaging systems, whether embedded or not, such as kV for 2×2D acquisitions and especially kVCBCT for 3D acquisitions are however irradiating in a large volume including the target volume but also healthy tissue, with a theoretical risk of increased toxicity and second cancer. GSK2830371 in vitro It therefore appears very important both to optimize the absorbed dose due to IGRT practice but also to report it, especially in case of kVCBCT. The AAPM report published in 2018 (« Image guidance doses delivered during radiotherapy Quantification, management, and reduction ») proposes a management of image guidance doses delivered during radiotherapy. This report is the basis of this focus article that aims at giving orders of magnitude and proposing a management of image guidance doses delivered during radiotherapy in clinical practice. The dose delivered per kVCBCT is about 0.5 to 2 cGy at isocenter according to treatment site. As long as the calculation algorithms are not available in the treatment planning systems, it seems appropriate to use at least the published dose orders of magnitude. This estimate should ultimately allow the clinician to decide on the therapeutic strategy in the event of accumulation of positioning imaging sessions.

    In literature, there are no guidelines on how to prescribe dose in the case of radiosurgery (SRS) or stereotactic irradiation of multiple and adjacent BM. Aim of this work is to furnish practical proposals of dosimetric methods for multiple neighboring BM, and to make a literature review about the SRS treatment of multiple BM, comparing radiotherapy techniques on the basis of different dosimetric parameters.

    A theoretical proposal of dosimetric approaches to prescribe dose in case of multiple contiguous BM is done. A literature review between 2010 and 2020 was performed on MEDLINE and Cochrane databases according to the PRISMA methodology, with the following keywords dose prescription, radiosurgery, multiple BM. Papers not reporting dosimetric solutions to irradiate multiple BM were excluded.

    Only one article in the literature reports a practical modality of dose prescription for multiple adjacent BM. Thus, we proposed other five practical solutions to prescribe radiation dose in case of two or more neighboring BM, describing advantages and drawbacks of each method in terms of different dosimetric parameters.

Skip to toolbar